Counter Rate Indicator, 6-Digit Presettable Counters or Rate Indicators,Gemini 10060, RED LION
In Stock -- Expected to ship today
Price:
$375.00
| KVAL P/N: |
GEM10060 |
|
Mfg Name:
|
Red Lion
|
|
Counter Rate
Indicator, 6-Digit Presettable Counters or Rate Indicators,Gemini
10060, RED LION, 115 VAC
Description:
The Gemini 1000 and 2000 offer the features and performance of a
single/dual level preset counter or a programmable sample time rate
indicator in one economically priced package. The reliability of
solid-state MOS technology coupled with the flexibility of user
programmable functions makes these units ideally suited to handle
practically any preset control application.
As a counter, the Gemini 1000/2000 offers a choice of six (6)
programmable
counting modes to cover Bi-directional, Anti-Coincidence,
and Quadrature
applications. The input circuitry is switch selectable to
accept signals from a
wide variety of sources. In addition, the unit may be
programmed to register
counts on both edges of the input signal thus providing
frequency doubling
capability. The choice of several reset cycle modes along
with the compatibility
of count and control inputs to other RLC products, provides
added versatility for both stand-alone and systems counter needs.
As a rate indicator, the Gemini 1000/2000 features
crystal-controlled accuracy along with a variety of data sampling
times to allow the needed resolution for precision applications.
The combination of 5-digit scale factor and decade scale
multipliers provide a wide range of scaling correction for direct
readout in terms of units being measured.
The Gemini 2000 20 mA Current Loop Option provides the
capability of
two-way communications between the Gemini 2000 and a variety
of
equipment, such as a printer, remote terminal, or host
computer. The Baud rate
can be set to 300, 600, 1200 or 2400 baud. The format for
transmitted and
received data is 1 start bit, 7 data bits, 1 parity bit
(odd), and 1 stop bit. When
utilizing an external power supply (30 VDC max), up to 16
units can be
installed in the loop, each with an individual address. When
utilizing the
Gemini’s 20 mA current source, up to seven units can be
installed in a loop.
The Count value, Scale Factor, and Preset values can be
interrogated. The
Scale factor and Presets can be changed by sending the
proper command codes and numerical Data. Other functions such as
resetting the count, and a
combined transmit count and reset can also be performed.
Various “Print
Options” can be selected to automatically interrogate the
Count Value, Preset,
or Scale Factor by activating the “Print Request” terminal
when a printer is
being used, or by sending a “transmit per Print Options” (P)
command. All
command codes and numerical data are sent in ASCII.
The construction of the Gemini 1000/2000 features a zinc
die-cast bezel
offering maximum durability with a high quality appearance.
The sealed front
panel meets NEMA 4/IP65 specifications, for wash-down and/or
dust when
properly installed. Electrical connections are made via
pluggable terminal strips
at the rear of the unit. Clamp-type pressure plate terminals
accept stripped #14
AWG wire
without lugs.
Specifications
1. DISPLAY:
6-digit 0.56" (14.2 mm) High LED display.
2. POWER REQUIREMENTS:
AC Power: Switch selectable 115/230 VAC (±10%), 50/60 Hz, 20
VA
DC Power: 11 to 14 VDC @ 0.7 A max.
3. SENSOR POWER: +12 VDC (±25%) @ 100 mA max.
4. MEMORY: Non-volatile E2PROM memory retains all
programming
information and count value when power is removed or
interrupted.
5. INPUTS A & B: Switch selectable to accept count
pulses from a variety of
sources including switch contacts, outputs from CMOS or TTL
circuits, and
all standard RLC sensors.
11 to 14 VDC @ 0.7 A max.
3. SENSOR POWER: +12 VDC (±25%) @ 100 mA max.
4. MEMORY: Non-volatile E2PROM memory retains all
programming
information and count value when power is removed or
interrupted.
5. INPUTS A & B: Switch selectable to accept count
pulses from a variety of
sources including switch contacts, outputs from CMOS or TTL
circuits, and
all standard RLC sensors.
Current Sourcing - Unit provides 3.9 KÙ pull-down load for sensors
with
current sourcing outputs. Max. input voltage = 28 VDC @ 7
mA.
Current Sinking - Unit provides 7.8 KÙ pull-up load for sensors
with
current sinking outputs. Max. sensor current = 1.6
mA.
Debounce - Damping capacitor provided for switch contact
debounce.
Limits count speed to 100 Hz max. with 50% duty cycle.